Cannula

Cannula

Flexible wings are designed with 6° angle
Triple facetted back cut & highly polished Japanese Needle with Ribbed Cap-Protective
Kink-resistant Catheter with color coded injection port
Clear and transparent chamber flash back product, features Flexible wings are designed with 6° angle for better placement & insertion of catheter on patient’s body. Wings are specially treated to provide easy & secure fixation with the patient skin.
Kink-resistant Catheter with improved double tapered, bevelled & siliconized tip to minimize trauma during venipuncture.
Catheter is thin-walled for increased flow rate with high chemical resistance to reduce chances of thrombogenecity.
Triple facetted back cut & highly polished Japanese Needle reduces penetration force and optimizes insertion performance.
This hypodermic, sharp bevelled stainless steel (AISI 304) needle is siliconized to minimize the chance of inadvertent nerve damage.
Injection port is color coded with non-return silicon value provided for intermittent medication.
Chamber flash back is clear and transparent to help visualize blood, which ensures successful venipuncture.
Cap-Protective is ribbed, designed to avoid deformation, which could otherwise lead to needle damage.










Disposable Cardioplegia Perfusion Set

Code Specification
2201 Crystalloid
2202 Blood
2203 Customized
Isolator

Code Specification
2401 Half Volume
2402 Full Volume
Heart Aspirator
Code Specification
33201 Adult
33202 Pediatric

Code Specification
33401 Adult
33402 Pediatric

Code Specification
33301 Adult












Left Heart Catheter (Vent line)
Code Specification
37104 18Fr

Code Specification
37101 16Fr
37102 18Fr
37103 20Fr

Code Specification
37401 14Fr
37402 16Fr
37403 20Fr
Sump

Code Specification
37301 Adult
37302 Pediatric
Cardioplegia Adapters

Code Specification
39001 Y Type
39002 5 Ways
39003 6 Ways
690101 1/4-Male Lure












Coronary Artery Ostial Cannula

45? tip 90? Tip
Specification Code Code
10Fr 38101 38102
12Fr 38201 38202
14Fr 38301 38302
Tubing Organizer

Code
6801
Blower

Code
9001


Tourniquet

Code Specification
36 14cm
3602 17.8 cm
Temperature Controlling Blanket with Water Circulation

Code Specification Size
2601 Adult 1.50×0.55m
2602 Pediatric 1.20×0.55m
2603 Infant 1.00×0.55m
Disposable Extra-Corporeal Circuit Tube

Code Specification
2101 Adult
2102 Pediatric
2103 Infant


Disposable Arterial Filter with Vent Line

Code Specification Max Flow rate(L/min) Filtrate area (cm2) Filtrate size(μm) Priming volume(mL)
2211 Adult 7.0 600 40 160
2212 Pediatric 3.0 300 40 100
2213 Infant 1.5 150 40 50
2214 Neonate 1.5 150 40 30